The OTN6500 optical transmission network system, which is mainly used in metro convergence layer and metro core layer, is a new generation of optical transmission system with high integration, high capacity, and long-distance.
The equipment applies advanced transmission technology and highly integrated technology, facing the whole IP transmission. It provides a function of wide bandwidth, high capacity, and fully transparent transmission, which can realize smooth capacity upgrade, offers a comprehensive, flexible, and mature protection solution, and provide a stable platform for multiple service operation and future network upgrade and expansion.
Huge capacity transmission and capacity of Modular upgrade
It supports 96 wavelengths 10G system transmission at the C band.It supports an access rate of up to 100Gbit/s for a single channel.
It supports a single-level multiplexing/demultiplexing architecture for 80/96 wavelength, without the need for OCI to implement multiplexing/demultiplexing for 80 wavelengths.
It supports a system expansion for 40/48->80/96 wavelength and also a modular expansion for 10G->100G, which ensures the low investment in the early stage of the network construction and the smooth expansion in the late stage, so as to meet the future growing demand in bandwidth.
Multi-rate, multi-protocol, full-service access, and convergence
Access to SDH/SONET services, data services of POS, GE, 10 GE, 40 GE, 100 GE, and other services of SAN, CPRI at various rate levels.The powerful capacity of service convergence, supporting 8xFE service convergence, 8×GE service convergence, and 10×10GE service convergence.
High integration, green, convenient maintenance
1U frame supports up to 4 service slots, with a super high level of integration.2U frame supports up to 8 service slots, with a super high level of integration.
5U frame supports up to 18 service slots, with a super high level of integration.
Compact structure and flexible installation, available for installation in the cabinet with 300 mm depth.
It supports free-of-configuration installation, and the equipment is plug-and-play.
It supports a unified network management platform and provides a perfect performance monitoring ability in the performance of networks and equipment.
The lowest power consumption in the industry, assist operators to build a green energy-saving network.
Outstanding architecture design and secure data transmission.
It offers a variety of network-level protection and provides comprehensive protection for optical fiber lines and services.
It provides comprehensive equipment protection: power equipment protection, fan protection.
The all-service transparent transmission reduces the transmission delay of circuit cross and ensures the reliability of transmission.
All-optical interfaces are pluggable and reusable, which reduces the investment of spare parts.
SPECIFICATIONS
Parameters | OTN6500-1U | OTN6500-2U | OTN6500-5U |
Equipment size | 1U:44 mm (height)x442 mm (width)x220 mm (depth) | 2U: 88 mm (height)x442 mm (width)x220 mm (depth) | 5U: 220 mm (height)x442 mm (width)x220 mm (depth) |
Service slot | 4 slots (network management card is optional for one of the slots) | 8 slots (network card is optional for one of the slots) | 18 slots for DC equipment (network card is optional for one of the slots) 16 slots for AC equipment (network card is optional for one of the slots) |
Transmission capacity of Single equipment | 16*10G bidirectional transmission 32*10G unidirectional transmissions |
32 wavelength* 10G bidirectional transmission 64 wavelength* 10G unidirectional transmission 4 wavelength* 10G unidirectional and bidirectional transmission |
DWDM: 96 wavelengths; CWDM: 16 wavelength |
Wavelength | CWDM: 1271nm~1611nm | CWDM:1271nm~1611nm | DWDM: C- Band, 100GHz or 50GHz |
DWDM: C Band, 100 GHZ or 50 GHZ | DWDM:C Band, 100 GHZ or 50 GHZ | CWDM: 1271nm~1611nm | |
The maximum rate of Single channel | 10Gbit/ s | 100Gbit/ s | 100Gbit/s |
Transmission distance | 80km (without optical amplification) | For DWDM system, it supports the maximum transmission distance of 130km (36 DB) for a single span For CWDM system, it supports a maximum transmission distance of 80 km |
For DWDM system, it supports the maximum transmission distance of 130km (36 DB) for a single span For CWDM system, it supports a maximum transmission distance of 80 km |
Service interface type | STM-1/4/16/64/256, OC-3/12/48/192/768 any service of 100M~2.5Gbps FE/GE/10GE/40GE/100GE ESCON/FICON/FICON Express, FC100/FC200/FC400/FC800/FC1200/SAN EPON, GPON, CPRI 1/2/3/6/7 |
STM-1/4/16/64/256, OC-3/12/48/192/768 any service of 100M~2.5Gbps FE/GE/10GE/40GE/100GE ESCON/FICON/FICON Express, FC100/FC200/FC400/FC800/FC1200/SAN EPON, GPON, CPRI 1/2/3/6/7 |
STM-1/4/16/64/256, OC-3/12/48/192/768 any service of 100M~2.5Gbps FE/GE/10GE/40GE/100GE ESCON/FICON/FICON Express, FC100/FC200/FC400/FC800/FC1200/SAN EPON, GPON, CPRI 1/2/3/6/7 |
Clock features | Support IEEE 1588 V2 | Support the IEEE 1588 V2 | Support IEEE 1588 V2 |
Optical connector | SFP/SFP +, LC type interface | SFP/SFP +, LC type interface | SFP/SFP +, LC type interface |
Network topology | Point to point, chain type, star type, ring type | Point to point, chain type, star type, ring type | Point to point, chain type, star type, ring type,ring-with-chain type, ring-cross type, ring-tangency type |
Installation | "19"and "23" cabinets, ETSI 300mm/600mm cabinets Wireless outdoor base station cabinet, FTTx outdoor cabinet, hanging wall |
"19"and "23" cabinets, ETSI 300mm/600mm cabinets Wireless outdoor base station cabinet, FTTx outdoor cabinet, hanging wall |
"19"and "23" cabinets, ETSI 300mm/600mm cabinets |
Working temperature range | -10 ℃~60 ℃ (typical) | - 10 ℃~60 ℃ (typical) | -10 ℃~60 ℃ (typical) |
Working humidity range | 5~95% no condensation | 5~95% no condensation | 5~95% no condensation |
Storage temperature range | -40℃~85℃ | -40℃~85℃ | -40℃~85℃ |
Heat dissipation | Fan cooling | Fan cooling | Fan cooling |
Power supply mode | AC: 90~260 V or DC: -36~-72 V (support 1+1 backup power input) | AC: 90~260V or DC: -36~-72 V (support 1+1 backup power input) | AC: 90~260V or DC: -36~-72 V (support 1+1 backup power input) |
Power consumption | 60W (typical) | 120W (typical) | 300W (typical) |
Backup and protection | Client-side 1+1protection, 1+1 protection inside board, optical multiplex section 1+1 protection, optical line 1+1 protection | Client-side 1+1protection, 1+1 protection inside board, optical multiplex section 1+1 protection, optical line 1+1 protection | Client-side 1+1protection, 1+1 protection inside board, optical multiplex section 1+1 protection, optical line 1+1 protection |
Power supply backup | Power supply backup | Power supply backup | |
Fan backup | Fan backup | Fan backup |
Worldwide FREE Shipping on orders over US$179
We offer FREE shipping on orders over US$179 WORLDWIDE by FedEx, DHL or UPS! We ship orders Monday through Friday from our warehouses. Most of the orders will be processed and shipped within 1~2 business days, excluding some custom items. The specific shipping time varies on the destination, shipping service you choose, and customs clearance. If you have a strict delivery time requirement, you may contact the sales representative before your purchase, and we will recommend you an appropriate shipping method. According to shipping methods, delivery time around the world is estimated as follows:
- FedEx Estimated 3-6 business days
- DHL Estimated 3-6 business days
- UPS Estimated 3-6 business days
Extended 30-day, no-questions-asked Return Policy
We have a 30-day, no-questions-asked return policy for all of our products. If you aren’t satisfied, please contact our team within 30 days of receipt for a refund or replacement. To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original and unopened packaging. To initiate a return please contact our customer success team who will issue an RMA number and provide return shipping instructions.
How to Track your orders
Once your package leaves our warehouse, we'll send you a shipment notification email. This email includes the carrier name, tracking number, shipping date and items' details. You can click the tracking number to track your package on the carrier's website, like DHL, FedEx or UPS.